Tank production & installation
- 7 PEHD tanks produced — 2 black water, 2 grey water, 3 transfer tanks
- 2 stainless steel fuel tanks produced
Tanks are designed around volume, installation space, inlet/outlet connections, venting and service access.
08WASTE WATER & SANITATION SYSTEMS
Installation, revision and fault finding on grey and black water tanks, macerators, transfer pumps, level sensors, vents and carbon filters, deck discharges and marine toilet systems.

We solve odour, backflow and blockage problems not in a single part, but together with the tank, vent, line fall and pump arrangement.
01Which problems do we solve?
We determine whether the problem comes from the tank, the vent and carbon filter, line fall and connections, or a pump or sensor — and apply a lasting fix.
02Scope of service
Installation, revision and fault finding on grey and black water tanks, macerators, transfer pumps, level sensors, vents and carbon filters, deck discharges and marine toilet systems.
Tanks are designed around volume, installation space, inlet/outlet connections, venting and service access.
Authorized commercial relation
We have an official commercial relationship with CEKA for tank and technical product solutions.
03How does the system work?
Overboard discharge is subject to local rules and marina requirements. Most odour problems come from venting, line fall and tank connections.
04Our service approach
We assess the sanitation system together with the toilets, tank, vent, carbon filter, pumps and discharge lines. Without addressing line fall, connection tightness, hose condition and tank venting together, odour and backflow problems cannot be solved for good.
05Service process
Our goal is not just to get a system running again, but to hand it over correct and serviceable.
Tank, lines, vent, pumps, sensors and toilet system are checked.
The source of odour, backflow, blockage or level errors is identified.
Tank, line, filter, pump or sensor revision is defined.
Installation, line renewal, tank and equipment work is carried out.
Emptying, transfer, tightness and level functions are tested.
06Systems / brand examples
We work on marine toilets, macerators, transfer pumps and tank systems from different manufacturers, following manufacturer documentation.
07Real applications
08Frequently asked questions
Can’t find your answer? Just tell us the system and the marina.
Ask a questionUsually because of a blocked or undersized vent, a saturated carbon filter, old hoses that let odour through, waste left standing in the tank or leaking connections. Odour treatments without finding the source are only temporary.
It depends on usage and the manufacturer’s recommendation; a seasonal check and replacement when odour returns are recommended.
Yes. PEHD and stainless tank solutions can be designed for the available space and the need, with inlet/outlet, vent and sensor connections planned from the start.
Next step
Tell us the symptom, the tank type and where the boat is; we’ll share an inspection plan.